National Repository of Grey Literature 8 records found  Search took 0.01 seconds. 
Heat pumps in heating systems
Zaťková, Miroslava ; Horák, Petr (referee) ; Počinková, Marcela (advisor)
This master´s thesis addresses heating of the new three - storey office building, which is located in Brno Pisárky. The heating system is designed as a low-temperature system with forced circulation of water using mostly panel radiators. As the heat source was designed two variants. The first heat source is the heat pump air - water, which is installationed inside. The second heat source is a gas condensing boiler. The part of design is preparation hot water. Ventilation of the building is equal-forced. Experimental part of master´s thesis is focused on measuring the amount of electricity produced per year by photovoltaic panels on the existing house in Brno Pisárky. Thesis also includes measuring outdoor temperature and intensity of solar radiation. The result is a comparison of the need for electricity for the heat pump for heating family house, total electricity consumption family house and amount of electricity produced by photovoltaic panels.
Use of renewable energy sources for heating
Heneková, Barbara ; Počinková, Marcela (referee) ; Horák, Petr (advisor)
This work is solving the proposal of underfloor heating office building. The theoretical part focused on the characteristics of heat pumps.The computational part is making a proposal for underfloor heating. The warm source is a heat pump of air and water, located in the exterior. The work includes a proposal for the all needed equipement and also the design of the source of warm water.
Radiators and microbial microclimate
Raputa, Pavel ; Rubinová, Olga (referee) ; Počinková, Marcela (advisor)
This master thesis describes the design of heating in a new one-storey nursery school in Kuřim. The heating systém is designed as a low-temperature systém with a forced circulation of water and a horizontal piping. Three kinds of radiators are used in the design. The panel radiators, tube radiators and free-standing convectors. In this project there are two varinats of the heat source for buliding. The first variant is two gas condensing boilers and the second variant is two heat pumps of an air/water split design. The disign includes air heating in the unit of air conditioning and hot water preparation. The experimental part of the master thesis is focused on microbial microclimate in buildings and radiators contamination by microorganisms. It contains four different experiments, their realization, results and evaluation.
Heating of kindergarten
Železná, Karolína ; Komínek, Petr (referee) ; Počinková, Marcela (advisor)
The objective of the bachelor thesis is a nursery school heating system design. The first, theoretical part, introduces the topic of underfloor heating. The computational part describes the design of a low-temperature heating system combining radiators and water underfloor heating, the design of a hot water preparation and other necessary equipment. Two air/water heat pumps are designated as energy sources. Ventilation is mechanical by air conditioning unit. The school is designed as a nearly zero-energy building.
Heating of kindergarten
Železná, Karolína ; Komínek, Petr (referee) ; Počinková, Marcela (advisor)
The objective of the bachelor thesis is a nursery school heating system design. The first, theoretical part, introduces the topic of underfloor heating. The computational part describes the design of a low-temperature heating system combining radiators and water underfloor heating, the design of a hot water preparation and other necessary equipment. Two air/water heat pumps are designated as energy sources. Ventilation is mechanical by air conditioning unit. The school is designed as a nearly zero-energy building.
Use of renewable energy sources for heating
Heneková, Barbara ; Počinková, Marcela (referee) ; Horák, Petr (advisor)
This work is solving the proposal of underfloor heating office building. The theoretical part focused on the characteristics of heat pumps.The computational part is making a proposal for underfloor heating. The warm source is a heat pump of air and water, located in the exterior. The work includes a proposal for the all needed equipement and also the design of the source of warm water.
Radiators and microbial microclimate
Raputa, Pavel ; Rubinová, Olga (referee) ; Počinková, Marcela (advisor)
This master thesis describes the design of heating in a new one-storey nursery school in Kuřim. The heating systém is designed as a low-temperature systém with a forced circulation of water and a horizontal piping. Three kinds of radiators are used in the design. The panel radiators, tube radiators and free-standing convectors. In this project there are two varinats of the heat source for buliding. The first variant is two gas condensing boilers and the second variant is two heat pumps of an air/water split design. The disign includes air heating in the unit of air conditioning and hot water preparation. The experimental part of the master thesis is focused on microbial microclimate in buildings and radiators contamination by microorganisms. It contains four different experiments, their realization, results and evaluation.
Heat pumps in heating systems
Zaťková, Miroslava ; Horák, Petr (referee) ; Počinková, Marcela (advisor)
This master´s thesis addresses heating of the new three - storey office building, which is located in Brno Pisárky. The heating system is designed as a low-temperature system with forced circulation of water using mostly panel radiators. As the heat source was designed two variants. The first heat source is the heat pump air - water, which is installationed inside. The second heat source is a gas condensing boiler. The part of design is preparation hot water. Ventilation of the building is equal-forced. Experimental part of master´s thesis is focused on measuring the amount of electricity produced per year by photovoltaic panels on the existing house in Brno Pisárky. Thesis also includes measuring outdoor temperature and intensity of solar radiation. The result is a comparison of the need for electricity for the heat pump for heating family house, total electricity consumption family house and amount of electricity produced by photovoltaic panels.

Interested in being notified about new results for this query?